>>> About Us
>>> Price-list
Aviation Low-intensity obstruction lights
ZOM-1-AL™ >10cd, ICAO
type «A»
50-265V AC / 30-350V DC.

“ZOM-1-AL”™ low intensity, type “A” obstruction
lights are a new market solution, intended for barrage lighting high-rise
objects, suggested by us in 2015. Consists of an anodized aluminum housing with
DOW® (Switzerland) optic polycarbonate light lens. These obstruction
lights were developed, considering our ten years manufacturing experience and
business cases from finest national specialists in the field of
telecommunications, construction and electric engineering. Our goal is to
provide high-quality optimum solutions in the form of modern and stable
equipment, living up to all needs and expectations. “ZOM-1-AL”™ obstruction lights filter is
equipped with an echelon lens. Quality supervision on all manufacture and
shipment stages provides complete exclusion of defective goods claims.
Purpose of the device:
“ZOM-1-AL”™ low intensity, type “A”
obstruction lights are intended for marking high-rise objects (obstructions)
potentially dangerous for air traffic: tall buildings and structures,
smoke-stacks, telecommunication
towers, mobile communications relay masts, water towers, chimneys, power lines, cooling towers, crane
installations, bridge supports, structures located in airports vicinity.
Benefits of our solutions:
·
Broad supply voltage band allows connecting our obstruction lights to
alternating and direct current without observation of polarities.
·
Built-in status monitoring system allows working capacity remote control
(full obstruction lights complex as well as each obstruction light separately).
·
Status monitoring system contains
galvanically isolated, normally-closed contacts allowing seamless integration
into any remote monitoring system.
Key features:
·
Based on LED-technology;
·
Extremely reliable – long lifetime;
·
Very low power consumption;
·
50-265V AC or 30-350V DC nominal operating voltage;
·
Stabilized light output;
·
Easy to install, several mounting sets available;
·
No RF-radiations;
·
Two (2) years warranty;
·
Patented.
Benefits:
·
Long maintenance intervals;
·
Supply power voltage variations do not affect to light output;
·
Very low total lifetime costs;
·
Lightweight and small – low wind load factor.
Specifications met:
·
ICAO
International Standards and Recommended Practices: Aerodromes – Annex 14 Volume
1, 5th Edition, July 2009, Chapter 6: Low-intensity, Type “A” Fixed
Obstacle Light.
Optical characteristics:
· Colour aviation red;
· Horizontal radiation pattern: 360°;
· Vertical radiation pattern: the normalized value of 16°, the actual value of 24°;
· The intensity in the + 6°: the actual value of 25 cd;
· The intensity in the + 10°: the actual value of 14 cd;
· The intensity in the direction of -6°: the actual value of 13 cd;
· LED-supply current stabilized by constant current generator;
· Light output degradation less than 30% after 100 000 h of operation.

Electrical characteristics:
·
Operating
voltage range, U (in): 50-265V AC. 30-350V DC;
·
Input
electrical current AC / DC, I (in): 45 ... 200 mA;
·
Maximum
switching voltage contacts "Contr": 400V;
·
Maximum
switching current contacts "Contr": 100mA;
·
Maximum
power consumption: 3,5 W;
·
Over-voltage
protection.
Mechanical characteristics:
·
Performance:
W1 – all climate;
·
For
operation in all macroclimate areas on land and at sea;
·
“ZOM-1”™ low intensity obstruction lights are
resistant to frost, rain, salt spray, dynamic dust, vibration stress, solar
irradiation, acute temperature changes (thermal impact).
·
Degree
of protection IP 65;
·
Operating
temperature range -60°C to +50°C.
·
Wind
load with MS-EV60 mounting kit @ 200 km/h less than 40 N;
·
Lens:
transparent, red of impact-resistant polycarbonate optical UV stabilizer DOW®
(Switzerland);
·
Housing
material: anodized, marine grade aluminum body and end parts;
·
Weight:
not more than 0.7 kg.
General requirements to mounting and exploitation:
“ZOM-1-AL”™ low intensity obstruction lights are attached by
means of a carrier unit (tubular mast) with outer threading G 3/4”. “ZOM-1-AL”™ low intensity obstruction lights contain a stationary
LED module as a light source. This module requires no maintenance or replacement
during service life. In order to connect power supply and monitoring wires it
is necessary to unscrew the upper obstruction light (light filter) section from
its base frame and perform the connection. Upon “ZOM-1-AL”™ low intensity obstruction lights assembly it is
necessary to observe that the rubber seal is installed. Light filter cleaning
is to be performed if and when it is contaminated by means of clean cotton,
soft flannel or wash leather without any solvents and abrasive substances.
After cleaning the light bowl is to be wiped by cotton, slightly moistened in
alcohol.
Assembly types:

Packing:
Obstruction lights packing
under GOST 23216 for storage conditions 2 (c) GOST 15150. “ZOM-1-AL”™ obstruction lights are
packed in transport tare, providing protection from mechanical damage and
atmospheric condensation.
Accident Prevention:
In order to ensure safety
during exploitation of “ZOM-1-AL”™ obstruction lights it is forbidden to:
·
Replace the lamp with light sources having lower luminous intensity index;
·
Perform any works on “ZOM-1-AL”™ obstruction lights while
voltage is connected’
·
Assemble and operate obstruction lights with compromised insulation.
Manufacturer's warranty:
We guarantee faultless device operation during 2 years
in case of service regulations compliance!
Order Code:
·
ZOM-1-AL >10cd
Payment and Delivery:
We perform shipping to any region on Incoterms-2010
conditions.
Terms and delivery conditions are discussed individually.
Settlements are made by means of a bank transfer with
an advanced contract on delivery.
For purchase, please contact: info.aerosignal@gmail.com
>>> Back