>>> About Us
>>> Price-list
Aviation Low-intensity obstruction lights
ZOM-1™ >10cd, ICAO
type «A»
50-265V AC / 30-350V DC.

“ZOM-1”™ low
intensity obstruction lights are a brand new decision intended for fencing
high-rise objects, offered by is in 2015. These obstruction lights were
developed considering ten years of our company manufacturing experience and
business cases of finest specialists in the field of telecommunications,
construction and electric equipment. We have set a goal to provide optimum and
effective solutions in the form of modern and reliable equipment living up to
all needs and expectations. “ZOM-1”™ light
filter is equipped with an echelon lens. Quality supervision on all manufacture
and shipment stages provides complete exclusion of defective goods claims.
Purpose of the device:
“ZOM-1”™ low intensity, type “A”
obstruction lights are intended for marking high-rise objects (obstructions)
potentially dangerous for air traffic: tall buildings and structures,
smoke-stacks, telecommunication
towers, mobile communications relay masts, water towers, chimneys, power lines, cooling towers, crane
installations, bridge supports, structures located in airports vicinity.
Benefits of our solutions:
·
Broad
supply voltage band allows connecting our obstruction lights to alternating and
direct current without observation of polarities.
·
Built-in
status monitoring system allows working capacity remote control (full
obstruction lights complex as well as each obstruction light separately).
·
Status monitoring system contains galvanically
isolated, normally-closed contacts allowing seamless integration into any
remote monitoring system.
Key features:
·
Based
on LED-technology;
·
Extremely
reliable – long lifetime;
·
Very
low power consumption;
·
50-265V
AC or 30-350V DC nominal operating voltage;
·
Stabilized
light output;
·
Easy to
install, several mounting sets available;
·
No
RF-radiations;
·
Two (2)
years warranty;
·
Patented.
Benefits:
·
Long
maintenance intervals;
·
Supply
power voltage variations do not affect to light output;
·
Very
low total lifetime costs;
·
Lightweight
and small – low wind load factor.
Specifications met:
·
ICAO
International Standards and Recommended Practices: Aerodromes – Annex 14 Volume
1, 5th Edition, July 2009, Chapter 6: Low-intensity, Type “A” Fixed Obstacle
Light.
Optical characteristics:
·
Colour aviation red;
·
Horizontal
radiation pattern: 360°;
·
Vertical
radiation pattern: the normalized value of 16°, the actual value of 24°;
·
The
intensity in the + 6°: the actual value of 25 cd;
·
The
intensity in the + 10°: the actual value of 14 cd;
·
The
intensity in the direction of -6°: the actual value of 13 cd;
·
LED-supply
current stabilized by constant current generator;
·
Light
output degradation less than 30% after 100 000 h of operation.

Electrical characteristics:
·
Operating
voltage range, U (in): 50-265V AC. 30-350V DC;
·
Input
electrical current AC / DC, I (in): 45 ... 200 mA;
·
Maximum
switching voltage contacts "Contr": 400V;
·
Maximum
switching current contacts "Contr": 100mA;
·
Maximum
power consumption: 3,5 W;
·
Over-voltage
protection.
·
Mechanical
characteristics:
·
Performance:
W1 – all climate;
·
For
operation in all macroclimate areas on land and at sea;
·
“ZOM-1”™ low intensity obstruction lights are
resistant to frost, rain, salt spray, dynamic dust, vibration stress, solar
irradiation, acute temperature changes (thermal impact);
·
Degree
of protection IP 65;
·
Operating
temperature range -60°C to +50°C.
·
Wind
load with MS-EV60 mounting kit @ 200 km/h less than 40 N;
·
Lens:
transparent, red of impact-resistant polycarbonate optical UV stabilizer DOW®
(Switzerland);
·
Housing
material: shock-resistant polycarbonate with UV stabilizer Bayer Makrolon® (Germany);
·
Weight:
not more than 0.3 kg.
General requirements to mounting and exploitation:
“ZOM-1”™ low intensity obstruction lights are attached by
means of a carrier unit (tubular mast) with outer threading G 3/4”. “ZOM-1”™ low intensity obstruction lights contain a stationary
LED module as a light source. This module requires no maintenance or replacement
during service life. In order to connect power supply and monitoring wires it
is necessary to unscrew the upper obstruction light (light filter) section from
its base frame and perform the connection. Upon “ZOM-1”™ low intensity obstruction lights assembly it is
necessary to observe that the rubber seal is installed. Light filter cleaning
is to be performed if and when it is contaminated by means of clean cotton,
soft flannel or wash leather without any solvents and abrasive substances.
After cleaning the light bowl is to be wiped by cotton, slightly moistened in
alcohol.
Assembly types:

Packing:
Obstruction lights packing
under GOST 23216 for storage conditions 2 (c) GOST 15150. “ZOM-1”™ obstruction lights are
packed in transport tare, providing protection from mechanical damage and
atmospheric condensation.
Accident Prevention:
In order to ensure safety
during exploitation of “ZOM-1”™ obstruction lights it is forbidden to:
·
Replace
the lamp with light sources having lower luminous intensity index;
·
Perform
any works on “ZOM-1”™ obstruction lights while voltage is
connected;
·
Assemble
and operate obstruction lights with compromised insulation.
Manufacturer's warranty:
We guarantee faultless device operation during 2 years
in case of service regulations compliance!
Order Code:
·
ZOM-1
>10cd
Payment and Delivery:
We perform shipping to any region on Incoterms-2010
conditions.
Terms and delivery conditions are discussed
individually.
Settlements are made by means of a bank transfer with
an advanced contract on delivery.
For purchase, please contact: info.aerosignal@gmail.com